Products Description
Spacelabs Compatible SpO2 Adapter Cable
1. Intended Use
- Designed to extend and adapt Spacelabs patient monitors for pulse oximetry (SPo2) monitoring, ensuring accurate, real-time oxygen saturation and pulse rate data in critical care, anesthesia, and general patient monitoring scenarios.

This SPo2 Adapter Cable is the critical link between Spacelabs patient monitors and pulse oximetry sensors. Featuring a rectangular 10-pin male connector (Spacelabs monitor side) and a DB9F female connector (sensor side), it extends connectivity by 2.5m while maintaining 100% signal integrity. The medical-grade TPU cable resists EMI interference and physical wear, making it a reliable choice for continuous SPo2 monitoring .
2. Applicable User
- ICU Nurses and Critical Care Clinicians
- Biomedical Equipment Technicians (BMETs)
- Hospital Biomed Departments
- Spacelabs Monitor Users in Anesthesia/Perioperative Settings
3. Product Performance
- Signal Precision: Oxygen-free copper (OFC) conductors ensure SPo2 readings deviate by ≤0.1% from true values-vital for detecting hypoxemia in ICU patients.
- Durability: Reinforced strain reliefs and medical-grade TPU withstand 5,000+ bend cycles and 200+ disinfection cycles.
- Compatibility: Seamlessly integrates with Spacelabs monitors (e.g., Ultraview, 90369) and industry-standard DB9F SPo2 sensors.
Technical Specifications
| Parameter | Specification |
| Model | EX033 |
| OEM Part no. | 700-0030-00 |
| Cable Type | Spo2 Adapter cable |
| Connector Configuration | Rectangular 10-Pin Male (Spacelabs Monitor) → DB9F Female (SPo2 Sensor) |
| Cable Length | 2.5m (8.2ft) |
| Outer Jacket | TPU (Latex-Free, DEHP-Free, Biocompatible) |
| Compatibility | Spacelabs Ultraview, 90369, and Other Spacelabs Patient Monitors |
| Disinfection Compatibility | Alcohol Wipes, Hospital-Grade Cleaners (200+ Cycles) |
Features
- 1:1 Spacelabs OEM Compatibility
Engineered to match Spacelabs' original specifications, this cable eliminates "no signal" errors-guaranteeing seamless integration with Ultraview and 90369 series monitors.
- EMI-Shielded OFC Conductors
Unlike generic cables, our OFC conductors with EMI shielding block interference from medical devices (e.g., ventilators, infusion pumps), ensuring SPo2 waveforms are clear and artifact-free.
- 2.5m Flexible Reach
The 2.5m length lets clinicians position SPo2 sensors freely-critical for patient mobility in ICUs or during surgical repositioning.
- Clinical-Grade Durability
Reinforced strain reliefs at connectors and a tear-resistant TPU jacket survive the rigors of daily hospital use, from frequent handling to disinfection.
Application Scenarios
Purpose
This SPo2 Adapter Cable serves as the connective backbone for Spacelabs pulse oximetry, enabling:
- Accurate detection of hypoxemia (low oxygen levels) in critical care.
- Uninterrupted SPo2 monitoring during surgical procedures.
- Flexible patient monitoring setups without compromising signal quality.
Applicable Industry
- Hospitals & Critical Care Units
- Anesthesia & Perioperative Suites
- Biomedical Equipment Supply & Maintenance
Applicable Fields
- ICU Monitoring: Continuous SPo2 tracking for intubated or high-risk patients.
- Anesthesia: Real-time oxygen saturation monitoring during surgery.
- Biomed Maintenance: Upgrading or repairing Spacelabs monitor connectivity.
- Patient Transport: Extending SPo2 monitoring range during patient moves.

Usage Method
1. Connect to Monitor
Align the rectangular 10-pin male connector with the Spacelabs monitor's SPo2 port and push until it clicks.
2. Attach to SPo2 Sensor
Connect the DB9F female connector to the compatible SPo2 sensor (finger probe, ear probe, etc.).
3. Verify Connection
Power on the monitor and check for stable SPo2 and pulse rate readings. Adjust cable positioning to avoid kinks.
4. Clean After Use
Wipe the cable and connectors with alcohol wipes. Store in a dry, clean area away from sharp objects.
Summary
2.5m Compatible Spacelabs 700-0030-00 extension cable. It is for use with Nellcor sensors without Oximax technology.
700-0030-00



This cable is more than a connector-it's a guardian of respiratory safety. With 1:1 Spacelabs compatibility, EMI-shielded accuracy, and clinical-grade durability, it ensures clinicians get the precise SPo2 data needed to protect patient health in ICUs, ORs, and beyond. Backed by our engineering expertise, strict quality controls, and global certifications, it's the trusted choice for hospitals, biomed teams, and Spacelabs users prioritizing pulse oximetry excellence.
Whether you need to upgrade your monitor's connectivity or maintain reliable SPo2 tracking, our flexible ordering, fast lead times, and unwavering quality make us your ideal partner in patient monitoring connectivity.
Hot Tags: spo2 adapter cable 700-0030-00 for spacelabs, China, manufacturers, customized, bulk, buy discount, low price, high quality