Heal Force Speech Oximeter Portable Finger Clip Pulse Oxygen Saturation Tester Household Finger Pulse Oxygen Prince-100N
Feature
-Two-color OLED display, support four-way switching display
measurement data
-Can display blood oxygen saturation, pulse rate, blood perfusion
index, pulse intensity histogram, pulse volume waveform
-Voice broadcasts blood oxygen, pulse rate and automatically
analyzes abnormal pulse rhythm results
-12 sets of data storage, with memory function
-With spot measurement and continuous monitoring mode,
over-limit automatic sound and light alarm
-Good performance under weak perfusion and strong anti-interference
ability
-5 seconds out of value. High-performance MCU, greatly increasing the computing speed
-lmported chips. Equipped with European imported chips for more accurate capturing of blood oxygen pulse signal
-Optical frequency digital conversion technology. Adopt the second generation LFC PLUS optical frequency digital conversion technology to greatly improve the measurement accuracy
-Audible alarm. Automatic alarm in case of exceeding the limit, the upper and lower limits of the alarm can be set by yourself
-Smart power saving. Automatic power-on monitoring after the finger is inserted into the machine aautomatically shut down after 5s of finger removal






Q&A
Q: Why choose an oximeter with blood perfusion index (PI)?
A: PI is the blood perfusion index. The PI value reflects the pulsating blood flow, that is, the perfusion ability of blood flow. The larger the PI value, the better the limb perfusion, and the test results of blood oxygen saturation have more reference significance. Simultaneous measurement of PI can be used for screening of relatex diseases.
Q: What is included in pulse rhythm analysis?
A: 1 Slightly slow pulse rate with irregular pulse interval
2 The pulse rate is slightly faster
3 Pulse rate is too fast
4 Paroxysmal pulse rate is too fast
5 Slightly slower pulse rate
6 Slow pulse rate
7 Occasionally shortened pulse interval
8 Irregular pulse interval
9 Pulse rate is slightly faster with occasional pulse interval shortening
10 Pulse rate is slightly slow with occasional pulse interval shortening
11 No abnormal pulse rhythm
12 Signal quality is poor, please re-measure
Q: What are the factors that affect the inaccuracy of Spo2 measurement?
A: a) Indoor strong light interference
b) Nall polish or colored skin care products
c) Vigorous activity at the detection site
d) Measure blood pressure on the same side
f) The measurement enviroment temperature is too low