Description
Disposable Pressure Transducer
Place of Origin: China
Payment Terms: 100% T/T, Western Union, Paypal
Shipping Method: DHL, TNT, EMS, Fedex, UPS, by sea
Delivery Time: 1-3 days for sample,7-14 days for big order after payment.
Specifications:
*Ambient temperature: 0 to 40°C(32 to 104°F)
*Relative humidity: 0% to 80%
*Hyperbaric pressure: 86kPa-106kPa
*Materials: High Quality TPU Jacket cable, Gray
Product details:
| Product name | IBP transducer |
| Place of Origin | Guangdong, China |
| Brand Name | Greatmade |
| Compatibility | BD |
| Size | 224*113*45mm |
| Certifications | CE/ISO |
| Cable color | White |
| Cable Material | PVC Jacket |
| Patient End | BD |
| Weight | 50g |
| Type | Disposable Pressure Transducer |
| Package | individual pack |
| Warranty | 1 year |



1.Consistant accurate working during blood pressure monitoring.
2.100000 grade clean workshop and 100% finial test.
3.Sterile and individual pakage.
4.connectors compatible with most monitors.
5.Single/double/triple channel are options.
6.OEM/ODM are available.
7.IBP transducer with TE sensor chip
8.ISO CE approval
|
Main technical parameters and working environment requirements: |
||||
|
Disposable Pressure Transducer |
||||
|
Barometric pressure |
70~106Kpa |
|||
|
Relative humidity |
10~90% (non-condensing) |
|||
|
Operating pressure range |
-50 ~ + 300 mmHg |
|||
|
Sensitivity |
5.0μV/V/mmHg ±3% |
|||
|
Nonlinearity and hysteresis |
full-scale reading±1.5% |
|||
|
Input impedance |
1200Ω ~3200Ω |
|||
|
Zero pressure offset |
-20mmHg~+20mmHg |
|||
|
Thermal offset shift |
≤±0.3mmHg/°C |
|||
|
Offset drift |
After warm-up for 20 seconds, drift within 2 mmHg within 8 hours |
|||
|
Thermal span shift |
≤±0.1%/°C |
|||
|
Frequency response |
Standard pressure set (48 "/ 12") is 40 Hz; Separate sensor > 200 Hz |
|||
|
Defibrillator withstand |
Defibrillation depends on the final connection of the equipment. |
|||
|
Leakage current |
Leakage current is dependent on the final connection of the equipment |
|||
|
Overpressure load |
-400~+4000mmHg |
|||
|
Shock resistance |
Withstand falling from one meter for three times |
|||
|
Light sensitivity |
When exposed to a 3400°K tungsten light, candle light at 3000 feet, it's less than 1 mmHg under rated voltage. |
|||
|
Storage and transport environment requirements |
- 20 ° C~ + 60 ° C, < 90%(non-condensing), no corrosive gas and indoor ventilation, and to avoid high temperature and cold. |
|||
|
Contact with the human body |
≤168h |
|||
|
Intra-system velocity |
||||
|
Flow |
2-5mL/h |
|||
|
Intra-system velocity refers to the velocity under 6.00 VDC and 25°C, unless there are additional instructions. |
||||





Hot Tags: bd disposable pressure transducer, China, manufacturers, customized, bulk, buy discount, low price, high quality, invasive blood pressure transducer for monitoring, disposable medical cable, disposable medical sensor, disposable sensor transducer for monitoring, medical equipment cable, disposable cable for medical